Welcome to the sDHT Adoption Library, featuring NaVi
NaVi is a closed-environment AI research assistant that leverages a carefully curated library of more than 300+ vetted documents, including FDA guidance and industry best practices. NaVi helps you search and explore content across the sDHT Adoption Library and Roadmap using natural language questions.
The Library is intended to serve as a living resource. Content is added periodically as new guidance, standards, and peer-reviewed research are released.
Meet NaVi: Your AI-Powered Research Assistant
Library scope and selection
To ensure high-quality, relevant results, the Library follows a predefined scoping approach:
- Inclusions: FDA guidance, non-commercial standards, and peer-reviewed research (2018–Present) focused on sDHTs being used as measurement tools for medical products in U.S.-based clinical trials.
- Exclusions: Materials from single commercial entities, non-U.S. regulatory bodies (except select EMA guidances with direct U.S. cross-relevance), and conference proceedings, and conference proceedings.
Inclusion in the Library does not imply endorsement, completeness, or regulatory acceptability.
Library scope
Resources in the sDHT Adoption Library are identified using a predefined scoping approach and include publicly available FDA guidance, non-commercial standards and guidance, and peer-reviewed research relevant to sDHT use in U.S.-based clinical trials. Materials from single commercial entities, non-U.S. regulatory bodies, conference proceedings, and studies conducted exclusively outside the United States are excluded; inclusion does not imply endorsement or regulatory acceptability.
Last updated 2026: Library content is reviewed and updated on a periodic basis as new eligible materials become available.
Clinical Decision Support Software (2026)
Clinical Decision Support Software (2026)
Findings
The FDA classifies CDS software as Non-Device CDS only if it meets four specific criteria related to data inputs, information display, HCP support, and independent reviewability. Software functions that analyze medical images, signals from IVDs, or patterns from signal acquisition systems remain regulated as medical devices. Non-Device CDS must be intended for health care professionals and not for patients or caregivers. Automation bias and the time-critical nature of decision-making are key factors in determining whether an HCP can truly review the basis of a recommendation independently. If software provides a specific diagnostic or treatment directive rather than a list of options, it generally fails to meet the exclusion criteria.
Recommendations
Developers should ensure that software intended as Non-Device CDS provides a plain language description of the underlying algorithm and the data used for validation. The software or labeling must clearly identify the intended HCP user, the patient population, and the required input medical information. To support independent review, the software should highlight the source of its clinical recommendations, such as specific clinical practice guidelines or peer-reviewed studies. Developers are encouraged to use usability testing to verify that HCPs can understand the basis of recommendations without relying primarily on the software’s output. For multiple function products, developers should follow the FDA’s policy for assessing products that contain both device and non-device functions.
Regulatory Considerations
The FDA applies a risk-based approach to software oversight, focusing on functions that acquire or analyze complex medical data like ECG waveforms or genomic sequences. Software intended for time-sensitive or critical medical decisions is typically regulated as a device because the user lacks the time to independently verify the recommendation. The agency intends to exercise enforcement discretion for certain software functions that provide only one clinically appropriate recommendation if all other non-device criteria are met. Sponsors may use the Q-Submission process to discuss alternative approaches or clarify the regulatory status of specific software functions. Existing digital health policies continue to apply to software functions that meet the device definition, including mobile medical applications.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
General Wellness: Policy for Low Risk Devices
General Wellness: Policy for Low Risk Devices
Findings
General wellness products are defined by two factors: they are intended only for general wellness use and present a low risk to user safety. The FDA categorizes wellness uses into those relating to a general state of health (e.g., weight management, physical fitness, sleep) and those relating to chronic diseases where lifestyle choices are well-accepted to play a role in health outcomes. Products are not considered low risk if they are invasive, implanted, or involve technologies like lasers or radiation that require specific regulatory controls. Software functions intended for maintaining a healthy lifestyle that are unrelated to the diagnosis or treatment of a disease are explicitly excluded from the statutory definition of a medical device.
Recommendations
Manufacturers should ensure that claims for general wellness products are limited to sustaining or improving general health functions or encouraging healthy lifestyle choices for living well with chronic conditions. Disease-related claims must be supported by peer-reviewed scientific publications or official statements from healthcare professional organizations. Labeling and marketing communications must be consistent with and not exceed the product's stated intended use. For products using non-invasive sensing to estimate physiologic parameters, manufacturers should validate these outputs if they mimic values used clinically. If a product includes notifications to see a doctor, these should not name specific diseases or characterize outputs as pathological.
Regulatory Considerations
For products meeting the low-risk general wellness criteria, the FDA does not intend to enforce requirements such as registration and listing, premarket notification, or Quality Management System regulations. The FDA may coordinate with the Consumer Product Safety Commission to determine jurisdiction over specific products. If a product targets the diagnosis, screening, or management of a disease through alerts or clinical thresholds, it is generally not considered a general wellness product and is subject to standard medical device regulations. Industry members may contact the Digital Health Center of Excellence or use the Q-Submission process to discuss alternative approaches or clarify the regulatory status of a specific product.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Artificial Intelligence in Software as a Medical Device
Artificial Intelligence in Software as a Medical Device
The traditional medical device regulatory paradigm is not designed for the adaptive nature of AI/ML technologies, which can learn and change after they are on the market. A key benefit of AI/ML is its ability to improve performance by learning from real-world data, but this also presents a unique regulatory challenge. To ensure patient safety and device effectiveness, a new, flexible regulatory framework is required that can accommodate these iterative improvements. Transparency and robust monitoring are essential to manage the risks associated with evolving algorithms.
Recommendations
The FDA proposes a "Predetermined Change Control Plan" (PCCP) to be included in premarket submissions. This plan would specify the anticipated modifications to the device (the "what") and the methodology for implementing and validating those changes (the "how"). The development of "Good Machine Learning Practice" (GMLP) is encouraged to ensure that AI/ML algorithms are developed and validated using best practices. Manufacturers should implement robust real-world performance monitoring to ensure that their devices remain safe and effective after deployment.
Regulatory Considerations
The FDA is developing a new regulatory framework tailored to the unique aspects of AI/ML-based SaMD, which will leverage a TPLC approach. The agency has issued an "AI/ML SaMD Action Plan" that outlines its multi-pronged approach, including issuing draft guidance on PCCPs and promoting the harmonization of GMLP. The FDA is actively collaborating with stakeholders to foster innovation while ensuring patient safety. The agency maintains a public list of authorized AI/ML-enabled medical devices to enhance transparency.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations
Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations
AI-enabled medical devices require robust risk assessment to address data drift, bias, and transparency challenges.
The total product lifecycle (TPLC) approach is essential for managing AI-enabled devices, ensuring continuous oversight and updates.
There is a need for improved standardization in AI model validation and performance monitoring to ensure consistency in regulatory submissions.
Effective data management practices, including dataset representativeness and bias control, are critical for AI model development.
Cybersecurity vulnerabilities in AI-enabled medical devices must be proactively addressed to prevent risks to patient safety and data integrity.
Recommendations
AI-enabled device manufacturers should integrate Good Machine Learning Practice (GMLP) principles throughout the device lifecycle.
Marketing submissions should include comprehensive documentation of AI model development, validation, and performance monitoring.
Developers should implement transparency measures, such as model interpretability and explainability, to enhance user trust and understanding.
AI models must undergo rigorous bias evaluation to ensure equitable performance across diverse patient populations.
A predetermined change control plan (PCCP) should be established to allow safe and effective AI model updates post-market without additional FDA submissions.
Regulatory Considerations
FDA encourages early engagement through the Q-Submission Program for AI-enabled device manufacturers.
Compliance with FDA-recognized consensus standards, such as ANSI/AAMI/ISO 14971 for risk management, is recommended.
AI-enabled devices must meet labeling requirements, ensuring that users clearly understand model inputs, outputs, and performance metrics.
Post-market surveillance and continuous monitoring of AI model performance are necessary to ensure ongoing safety and effectiveness.
Cybersecurity measures must be included in regulatory submissions, detailing safeguards against data breaches and unauthorized model modifications.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Biomarker Qualification Program
Biomarker Qualification Program
The traditional process of evaluating biomarkers within the context of a single drug development program is inefficient and creates uncertainty for sponsors. This case-by-case approach leads to redundant efforts, slows down the development of novel therapies, and hinders the broad adoption of promising scientific tools. There is a clear need for a centralized, collaborative pathway to formally validate biomarkers, which can de-risk drug development, encourage innovation, and make the process more predictable and cost-effective for all stakeholders.
Recommendations
Drug developers, academic researchers, and other stakeholders should proactively engage with the FDA through the formal Biomarker Qualification Program to validate biomarkers for specific contexts of use. It is recommended to form public-private partnerships and other collaborations to pool resources and data, which strengthens the evidence package for a biomarker's utility. Developers should use the qualification process to establish a biomarker's value early, making it a publicly available and reliable tool that can accelerate the development of multiple drug products.
Regulatory Considerations
The Biomarker Qualification Program provides a distinct regulatory pathway for establishing a biomarker's validity for a specific Context of Use (COU), separate from an individual Investigational New Drug (IND) or New Drug Application (NDA). The process involves a three-stage submission and review cycle: the Letter of Intent, the Qualification Plan, and the Full Qualification Package. Once qualified, a biomarker is publicly listed and can be incorporated into multiple drug development programs without the need for sponsors to re-submit and re-justify the validation data for that specific COU, streamlining subsequent regulatory reviews.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Considerations for the Use of Artificial Intelligence To Support Regulatory Decision-Making for Drug and Biological Products, Draft, 2025 (FDA)
Considerations for the Use of Artificial Intelligence To Support Regulatory Decision-Making for Drug and Biological Products, Draft, 2025 (FDA)
The document introduces a risk-based credibility assessment framework for establishing and evaluating the credibility of an Artificial Intelligence (AI) model's output when used to support regulatory decisions regarding drug safety, effectiveness, or quality. The framework outlines a 7-step process beginning with defining the question of interest and the Context of Use (COU). Credibility is defined as trust, established through evidence, in the AI model's performance for a particular COU. The credibility assessment is tailored to the AI model risk, which is a combination of model influence (the AI model's evidence contribution relative to other evidence) and decision consequence (the significance of an adverse outcome from an incorrect decision). The document highlights challenges with AI use, including variability in development datasets (training/tuning), the need for methodological transparency due to model complexity, difficulty in quantifying and interpreting uncertainty in model output, and the potential for performance change over time (data drift), which necessitates life cycle maintenance.
Recommendations
Sponsors and interested parties should define the question of interest and clearly define the COU, detailing the AI model's specific role and scope and whether other information will be used. They should assess the AI model risk (low, medium, or high) to ensure that subsequent credibility assessment activities (Step 4) are commensurate with that risk and tailored to the COU. For Step 4, the credibility assessment plan should include a description of the model, model development process (including inputs, architecture, feature selection, and rationale), and data used (training and tuning data). Development data must be deemed fit for use (relevant and reliable) to mitigate issues like algorithmic bias. The plan should also detail the model evaluation process using independent test data and include performance metrics with confidence intervals, an estimate of uncertainty, and a description of model limitations. Early engagement with the FDA is strongly encouraged to discuss model risk and the adequacy of the credibility assessment plan.
Regulatory Considerations
The risk-based credibility assessment framework is intended to help organize and document information for regulatory submissions. The required stringency of assessment activities and the level of documentation should be commensurate with the AI model risk. For AI models whose performance can change over time (e.g., in pharmaceutical manufacturing or postmarketing), sponsors must implement life cycle maintenance plans to monitor performance and manage changes in a risk-based manner. Changes to AI models should be evaluated through the manufacturer's change management system and may require re-execution of parts of the credibility assessment plan. Early engagement can be facilitated through formal meetings (e.g., Pre-IND) or other specialized programs listed in the guidance, such as the Center for Clinical Trial Innovation (C3TI), the Model-Informed Drug Development (MIDD) Paired Meeting Program, and the Emerging Technology Program (ETP) or Advanced Technologies Team (CATT).
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Cybersecurity in Medical Devices Frequently Asked Questions (FAQs)
Cybersecurity in Medical Devices Frequently Asked Questions (FAQs)
Cybersecurity is an integral part of medical device safety and effectiveness, and manufacturers are responsible for addressing it throughout the entire device lifecycle. The FDA considers a device's cybersecurity as part of its benefit-risk assessment for both premarket and postmarket activities. A lack of robust cybersecurity controls can lead to patient harm, compromised device functionality, and breaches of data privacy. The dynamic nature of cybersecurity threats requires ongoing monitoring, risk management, and timely implementation of mitigation strategies.
Recommendations
Manufacturers should build cybersecurity into devices from the design phase ("secure by design") and conduct a thorough risk analysis to identify and mitigate potential vulnerabilities. Premarket submissions should include comprehensive documentation of the device's cybersecurity controls, a risk management plan, and a plan for postmarket surveillance and response. Manufacturers should establish a robust postmarket surveillance program to monitor for, identify, and address new cybersecurity threats in a timely manner. Clear and informative labeling is essential to help users understand and manage cybersecurity risks.
Regulatory Considerations
The FDA has the authority to take action against devices with inadequate cybersecurity that pose a risk to public health. The agency recommends that manufacturers use the Q-submission process to discuss specific cybersecurity questions related to their device submissions. Compliance with recognized standards and best practices for cybersecurity is strongly encouraged. Manufacturers must report certain cybersecurity incidents to the FDA as part of their postmarket reporting requirements. The FDA collaborates with other government agencies and stakeholders to promote a coordinated approach to medical device cybersecurity.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Digital Health Technologies (DHTs) for Drug Development
Digital Health Technologies (DHTs) for Drug Development
The central principle of the FDA's program is that Digital Health Technologies (DHTs) offer significant potential to make clinical trials more efficient, patient-centric, and capable of capturing novel data. A key finding is that a collaborative, multifaceted approach is necessary to address the challenges of incorporating DHT-derived data into regulatory decision-making. The program acknowledges that ensuring data quality, validating new endpoints, and establishing clear regulatory expectations are critical for the successful adoption of these technologies in drug development.
Program Activities (Recommendations)
The FDA's activities in this area function as implicit recommendations for the industry. The agency is actively:
Developing a Framework: Creating and publishing a clear framework to guide the use of DHTs in drug and biological product development.
Engaging Stakeholders: Convening public meetings and workshops to foster collaboration and share learning among patients, biopharmaceutical companies, DHT manufacturers, and academia.
Supporting Demonstration Projects: Funding and overseeing research projects to address critical gaps and demonstrate the reliability and validity of specific digital measures.
Building Internal Expertise: Establishing a DHT Steering Committee and enhancing internal knowledge to ensure consistent and expert review of submissions containing DHT-derived data.
Regulatory Considerations
This webpage emphasizes the FDA's commitment to creating a clear regulatory framework for the use of DHTs in drug development. It highlights that while DHTs offer great promise, they also present new regulatory challenges related to data integrity, validation, and analysis. The FDA's approach involves a combination of issuing new regulatory guidance, promoting stakeholder collaboration, and advancing regulatory science. Sponsors are encouraged to engage with the FDA to discuss their use of DHTs in clinical trials to ensure alignment with the agency's expectations. The establishment of the CDRH Digital Health Center of Excellence provides a dedicated resource for such engagement.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Drug Development Tool (DDT) Qualification Programs
Drug Development Tool (DDT) Qualification Programs
The central principle of the DDT Qualification Programs is to create a formal pathway for the FDA to conclude that a specific tool is well-suited for a particular Context of Use (COU) in drug development. A key finding, as reflected in the program's design, is that qualification de-risks drug development by allowing a tool to be used in any regulatory submission for its qualified COU without needing to be re-validated each time. The program is designed to foster stakeholder collaboration, encouraging the development of tools that can benefit the entire research community, thereby reducing the burden on individual sponsors.
Program Activities (Recommendations)
The structure of the DDT programs serves as a series of recommendations for tool developers:
Engage Early and Collaboratively: The programs are designed to provide a framework for early and ongoing scientific collaboration with the FDA to facilitate the development of new tools.
Follow a Staged Process: Developers are guided through a multi-stage process, typically involving a Letter of Intent, a Qualification Plan, and a Full Qualification Package, to systematically build the evidence needed for qualification.
Seek Public Qualification: The ultimate recommendation is to achieve public qualification for a DDT, which makes the tool available for broad use and integrates it into the regulatory review process, expediting future drug development.
Regulatory Considerations
The DDT Qualification Programs are a formal regulatory framework established under the 21st Century Cures Act. A "qualified" DDT has a specific regulatory status; it can be relied upon to have a specific interpretation and application in drug development and regulatory review for its stated Context of Use (COU). This qualification is publicly available and allows the tool to be included in Investigational New Drug (IND), New Drug Application (NDA), or Biologics License Application (BLA) submissions without the FDA needing to reconsider its suitability. This creates a more efficient and predictable regulatory compliance pathway for sponsors who use the qualified tool.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Electronic Submission Template for Medical Device Q-Submissions
Electronic Submission Template for Medical Device Q-Submissions
This guidance establishes that the eSTAR platform will become the mandatory format for the electronic submission of medical device Pre-Submissions to the FDA. A key principle is that a properly completed eSTAR submission is considered a 'complete' submission, which allows it to bypass the traditional Refuse-to-Accept (RTA) process and instead undergo a more focused technical screening within 15 days. The structure of the eSTAR template is designed to align with the FDA's internal review memo, creating a more efficient and consistent review process. The guidance also makes it clear that while eSTAR use is currently voluntary, it will become required for Pre-Subs at least one year after this guidance is finalized.
Recommendations for Industry
The primary recommendation for industry is to familiarize themselves with and begin voluntarily using the eSTAR platform for Pre-Submissions in advance of the mandatory deadline. The guidance recommends that submitters use the structured, dynamic PDF to ensure all necessary elements of a complete submission are included, thereby facilitating a smoother and more efficient review. For certain types of follow-up communications, such as submitting meeting minutes or presentation slides, the guidance recommends they continue to be submitted as an eCopy rather than through the eSTAR template.
Regulatory Considerations
This guidance is issued under the authority of the Federal Food, Drug, and Cosmetic (FD&C) Act, which mandates the transition to electronic-only submissions. Upon finalization, the requirement to use the eSTAR template for Pre-Subs will be a binding regulatory requirement. The guidance outlines a specific technical screening process for eSTAR submissions that will replace the RTA process. If a submission fails this screening, it will be placed on hold, and the review clock will restart upon receipt of the corrected information. The document also specifies certain types of submissions, such as appeals and withdrawal requests, that will be exempt from the mandatory eSTAR requirement.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Has FDA’s Drug Development Tools Qualification Program Improved Drug Development?
Has FDA’s Drug Development Tools Qualification Program Improved Drug Development?
Long and Unpredictable Timelines: The COA Qualification Program is lengthy and unpredictable, with an average qualification time of six years. Nearly half of all submissions experience review times that exceed the FDA's own published targets.
Low Qualification and Uptake: As of October 2024, only seven COAs (8.1% of those listed) have been qualified, and only three of those have been used to support the benefit-risk assessment of new medicines. No COAs submitted after the passage of the 21st Century Cures Act in 2016 have been qualified.
Limited Regulatory Impact: Qualified COAs are consistently designated for "exploratory use" and have never been accepted as a primary endpoint in a clinical trial. In contrast, some non-qualified COAs have been used as key endpoints and included in drug labels, questioning the utility of the formal qualification pathway.
Discrepancy Between FDA Centers: There is a notable difference in how COAs are qualified between the drug (CDER/CBER) and device (CDRH) centers. The Kansas City Cardiomyopathy Questionnaire (KCCQ) was qualified by CDRH for use as a primary or secondary endpoint, while for drugs, it was only qualified as an "exploratory" measure.
Recommendations
Increase Transparency of Timelines: The FDA should publish its actual, historical review timelines for COA qualification so that drug developers can better plan and integrate these tools into their development programs.
Clarify the Use of Qualified COAs: The FDA should clearly articulate how and when qualified COAs can be used as primary or secondary endpoints to support regulatory decision-making and provide a clear pathway for updating a COA's status from "exploratory" to a key endpoint.
Publish Best Practices: Both sponsors and the FDA should be encouraged to publish their experiences with the qualification program to share best practices and learnings with the broader drug development community.
Create a List of Accepted Endpoints: The FDA should create and maintain a public list of qualified COAs that can be used as surrogate endpoints to support drug approval decisions, thereby increasing their utility and adoption.
Regulatory Considerations
"Qualified as a Measure" Ambiguity: The FDA's practice of qualifying COAs as "measures" for "exploratory use" creates regulatory uncertainty for sponsors, as it implies that significant additional evidence is still needed before the tool can be relied upon for a key endpoint.
Qualification is Not Required: The analysis shows that COAs can be accepted for regulatory decision-making and included in drug labels without going through the formal qualification program, suggesting that qualification is not a prerequisite for use as a reliable endpoint.
Unclear Path to Endpoint Progression: The current DDT guidance does not specify the process for upgrading a COA's qualification status (e.g., from exploratory to a primary endpoint) after additional data has been generated, which hinders its evolution and broader use.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
List of qualified DDTs
List of qualified DDTs
The database provides a transparent and accessible way for the public to track the progress of various Drug Development Tools (DDTs) through the FDA's qualification pipeline. This includes biomarkers, clinical outcome assessments, and animal models. The information available, such as submission status and supporting documentation, offers insight into the types of tools being developed and the evidence required for their qualification. The platform reveals that a wide range of tools are in development across numerous therapeutic areas, highlighting active areas of research and innovation in drug development.
Recommendations
Stakeholders in the drug development ecosystem are encouraged to utilize this database to inform their research and development strategies. By reviewing the status of existing DDT submissions, sponsors can identify opportunities for collaboration, avoid duplicative efforts, and better understand the evidentiary requirements for tool qualification. Prospective tool developers should use the database to learn from successful submissions and to align their own development plans with FDA expectations.
Regulatory Considerations
This database is a direct implementation of the transparency provisions of the 21st Century Cures Act. The public availability of this information is intended to foster trust and collaboration in the DDT qualification process. By providing a clear view of the regulatory journey of various tools, the FDA aims to standardize the qualification process and encourage the development and use of novel, validated tools in drug development. Users of the database should be aware that the information reflects the status of a DDT at a particular point in time and that the qualification process is an iterative one.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.