Welcome to the sDHT Adoption Library, featuring NaVi
NaVi is a closed-environment AI research assistant that leverages a carefully curated library of more than 300+ vetted documents, including FDA guidance and industry best practices. NaVi helps you search and explore content across the sDHT Adoption Library and Roadmap using natural language questions.
The Library is intended to serve as a living resource. Content is added periodically as new guidance, standards, and peer-reviewed research are released.
Meet NaVi: Your AI-Powered Research Assistant
Library scope and selection
To ensure high-quality, relevant results, the Library follows a predefined scoping approach:
- Inclusions: FDA guidance, non-commercial standards, and peer-reviewed research (2018–Present) focused on sDHTs being used as measurement tools for medical products in U.S.-based clinical trials.
- Exclusions: Materials from single commercial entities, non-U.S. regulatory bodies (except select EMA guidances with direct U.S. cross-relevance), and conference proceedings, and conference proceedings.
Inclusion in the Library does not imply endorsement, completeness, or regulatory acceptability.
Library scope
Resources in the sDHT Adoption Library are identified using a predefined scoping approach and include publicly available FDA guidance, non-commercial standards and guidance, and peer-reviewed research relevant to sDHT use in U.S.-based clinical trials. Materials from single commercial entities, non-U.S. regulatory bodies, conference proceedings, and studies conducted exclusively outside the United States are excluded; inclusion does not imply endorsement or regulatory acceptability.
Last updated 2026: Library content is reviewed and updated on a periodic basis as new eligible materials become available.
Clinical Decision Support Software (2026)
Clinical Decision Support Software (2026)
Findings
The FDA classifies CDS software as Non-Device CDS only if it meets four specific criteria related to data inputs, information display, HCP support, and independent reviewability. Software functions that analyze medical images, signals from IVDs, or patterns from signal acquisition systems remain regulated as medical devices. Non-Device CDS must be intended for health care professionals and not for patients or caregivers. Automation bias and the time-critical nature of decision-making are key factors in determining whether an HCP can truly review the basis of a recommendation independently. If software provides a specific diagnostic or treatment directive rather than a list of options, it generally fails to meet the exclusion criteria.
Recommendations
Developers should ensure that software intended as Non-Device CDS provides a plain language description of the underlying algorithm and the data used for validation. The software or labeling must clearly identify the intended HCP user, the patient population, and the required input medical information. To support independent review, the software should highlight the source of its clinical recommendations, such as specific clinical practice guidelines or peer-reviewed studies. Developers are encouraged to use usability testing to verify that HCPs can understand the basis of recommendations without relying primarily on the software’s output. For multiple function products, developers should follow the FDA’s policy for assessing products that contain both device and non-device functions.
Regulatory Considerations
The FDA applies a risk-based approach to software oversight, focusing on functions that acquire or analyze complex medical data like ECG waveforms or genomic sequences. Software intended for time-sensitive or critical medical decisions is typically regulated as a device because the user lacks the time to independently verify the recommendation. The agency intends to exercise enforcement discretion for certain software functions that provide only one clinically appropriate recommendation if all other non-device criteria are met. Sponsors may use the Q-Submission process to discuss alternative approaches or clarify the regulatory status of specific software functions. Existing digital health policies continue to apply to software functions that meet the device definition, including mobile medical applications.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Core Digital Measures of Pediatric Rare Disease
Core Digital Measures of Pediatric Rare Disease
Findings
Fragmented and inconsistent measurement approaches currently hinder the generation of decision-grade evidence for pediatric rare diseases. Small and geographically dispersed patient populations make traditional site-based clinical assessments operationally difficult and burdensome for families. Digital health technologies can capture subtle functional changes and "functional fingerprints" in home settings that are often missed during infrequent clinic visits. Standardized core digital measures across conditions allow for the aggregation of data and the creation of a shared evidence base for rare disorders. Meaningful aspects of health identified by patients and caregivers include motor function, communication, sleep quality, and autonomic stability.
Recommendations
Sponsors should adopt the core set of digital clinical measures to reduce trial timelines, lower development costs, and decrease participant burden. Researchers should prioritize passive and objective data collection to minimize the need for manual tracking by caregivers. Clinical trial designs should transition toward decentralized or hybrid models to improve access for children and families regardless of their location. Stakeholders should use the project's conceptual model to identify and customize digital measures that align with the specific health priorities of their target population. Developers should focus on human-centered design to ensure digital tools are usable and sustainable for pediatric patients and their support networks.
Regulatory Considerations
The FDA and EMA provide specific pathways and interaction opportunities to accelerate the acceptance of digital endpoints in rare disease trials. Digital measures must be validated as "decision-grade" endpoints to meet the evidentiary requirements for regulatory submission and marketing approval. Alignment with industry standards for data elements and interoperability is necessary to ensure data integrity across multi-site studies. Early engagement with regulatory bodies through meetings and formal submissions is critical for confirming the suitability of new digital biomarkers. Compliance with data privacy and ethical standards is paramount when collecting continuous, real-world data from vulnerable pediatric populations.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
General Wellness: Policy for Low Risk Devices
General Wellness: Policy for Low Risk Devices
Findings
General wellness products are defined by two factors: they are intended only for general wellness use and present a low risk to user safety. The FDA categorizes wellness uses into those relating to a general state of health (e.g., weight management, physical fitness, sleep) and those relating to chronic diseases where lifestyle choices are well-accepted to play a role in health outcomes. Products are not considered low risk if they are invasive, implanted, or involve technologies like lasers or radiation that require specific regulatory controls. Software functions intended for maintaining a healthy lifestyle that are unrelated to the diagnosis or treatment of a disease are explicitly excluded from the statutory definition of a medical device.
Recommendations
Manufacturers should ensure that claims for general wellness products are limited to sustaining or improving general health functions or encouraging healthy lifestyle choices for living well with chronic conditions. Disease-related claims must be supported by peer-reviewed scientific publications or official statements from healthcare professional organizations. Labeling and marketing communications must be consistent with and not exceed the product's stated intended use. For products using non-invasive sensing to estimate physiologic parameters, manufacturers should validate these outputs if they mimic values used clinically. If a product includes notifications to see a doctor, these should not name specific diseases or characterize outputs as pathological.
Regulatory Considerations
For products meeting the low-risk general wellness criteria, the FDA does not intend to enforce requirements such as registration and listing, premarket notification, or Quality Management System regulations. The FDA may coordinate with the Consumer Product Safety Commission to determine jurisdiction over specific products. If a product targets the diagnosis, screening, or management of a disease through alerts or clinical thresholds, it is generally not considered a general wellness product and is subject to standard medical device regulations. Industry members may contact the Digital Health Center of Excellence or use the Q-Submission process to discuss alternative approaches or clarify the regulatory status of a specific product.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
510(k) Premarket Notification
510(k) Premarket Notification
The Premarket Notification (510(k)) database is a critical component of the FDA's regulatory framework for medical devices. Its primary function is to house information on devices that have been cleared through the 510(k) pathway, which is the most common route to market for medical devices in the U.S.
A 510(k) submission's central requirement is to demonstrate "substantial equivalence" to a legally marketed predicate device. This means the new device is as safe and effective as a device already on the market. Clearance of a 510(k) does not denote "approval" in the same way as a Premarket Approval (PMA) application but rather confirms that the device meets the necessary criteria for marketing.
The database provides transparency and serves as an essential resource for manufacturers to identify potential predicate devices for their own submissions. For healthcare providers, patients, and researchers, it offers a way to verify the regulatory status and clearance basis for a specific device.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
A Hierarchical Framework for Selecting Reference Measures for the Analytical Validation of Sensor-Based Digital Health Technologies
A Hierarchical Framework for Selecting Reference Measures for the Analytical Validation of Sensor-Based Digital Health Technologies
The quality of evidence for the analytical validation of sensor-based digital health technologies (sDHTs), which is the evaluation of algorithms converting sensor data into a clinically interpretable measure, is often inconsistent and insufficient. The existing V3+ framework codifies the overall evaluation process, which includes verification, usability validation, analytical validation, and clinical validation. To improve the scientific rigor of analytical validation, a hierarchical framework for selecting reference measures is needed because not all potential reference measures are of equal quality. The framework classifies reference measures based on attributes that contribute to reduced measurement variability, with defining and principal measures being the most rigorous due to objective data acquisition and the ability to retain source data.
Recommendations
The proposed framework sequentially moves the investigator through four steps: (1) Compile preliminary information, including the digital clinical measure, context of use (COU), algorithm requirements, and sensor verification evidence . (2) Select an existing reference measure, develop a novel comparator, or identify a set of anchor measures, prioritizing measures with the highest scientific rigor (defining → principal → manual → reported) . (3) Consider the impact of the data collection environment to determine if the analytical validation study can be conducted in the intended use environment with the highest-order measure, or if in-lab validation is necessary, ensuring the results are generalizable . (4) Describe the rationale for key study design decisions to encourage transparency for evaluators, regulators, and payers . Investigators must justify passing over a higher-ranked reference measure, generally only acceptable if the higher-ranked measure poses unacceptable risk or is not applicable to the context of use.
Regulatory Considerations
The principles of the framework for analytical validation apply regardless of the regulatory status of the sDHT (regulated medical device, low-risk general wellness apps, or research product) or its intended use (clinical care or clinical research). The framework is intended to help investigators support the most rigorous claims regarding sDHT performance, which is important for acceptance by evaluators, peer-reviewers, regulators, and payers. The categorization of the digital clinical measure as a digital biomarker or an electronic clinical outcome assessment also does not change the framework's applicability.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Advancing the Integration of Digital Health Technologies in the Drug Development Ecosystem
Advancing the Integration of Digital Health Technologies in the Drug Development Ecosystem
Findings
The rapid advancement of sensor technology and connectivity has enabled high-frequency, longitudinal monitoring of physiological processes, yet the infrastructure for large-scale deployment remains resource-intensive. Current challenges include a lack of standardized terminology for digital decision-making tools and significant variability in environmental factors that affect sensor performance. Proprietary algorithms and device-specific barriers often hinder the verification and validation processes necessary for regulatory approval. Additionally, there is a distinct gap between granular digital features and their clinical relevance or meaningfulness to patients. Ethical concerns are emerging around data management, patient anxiety in psychiatric contexts, and the responsibility for addressing adverse events detected by remote monitoring.
Recommendations
Stakeholders should develop consensus-driven frameworks for standardized device performance reporting and environmental testing to streamline evaluations for specific contexts of use. The community should adopt a modular approach to data standards that bins requirements by concept of interest and disease-specific needs. Collaborative efforts between patients and developers are essential to bridge the gap between technical metrics and meaningful aspects of health. It is recommended to implement ""bring-your-own-device"" (BYOD) frameworks that ensure data reliability while supporting the inevitable evolution of technology during long-term studies. Researchers and clinicians must be trained in the ethical, legal, and social implications of digital health technology use, particularly regarding data privacy and the management of remote-detected safety signals.
Regulatory Considerations
Digital health technologies used to collect endpoints must meet high evidentiary requirements for validation, with complexity increasing when multiple sensors or complex software are bundled. Regulatory agencies like the FDA and EMA have established pathways for the qualification of drug development tools, including biomarkers and clinical outcome assessments. Integration of new draft guidance on remote health monitoring with existing regulatory workflows is necessary to reduce uncertainty in trial evaluations. While many digital health technologies do not qualify as medical devices unless they have a specific medical purpose, synergies between device risk assessments and drug trial data integrity frameworks should be explored. Early engagement with regulators remains a critical step for obtaining feedback on novel digital endpoints and ensuring the suitability of evidentiary support.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Artificial Intelligence in Software as a Medical Device
Artificial Intelligence in Software as a Medical Device
The traditional medical device regulatory paradigm is not designed for the adaptive nature of AI/ML technologies, which can learn and change after they are on the market. A key benefit of AI/ML is its ability to improve performance by learning from real-world data, but this also presents a unique regulatory challenge. To ensure patient safety and device effectiveness, a new, flexible regulatory framework is required that can accommodate these iterative improvements. Transparency and robust monitoring are essential to manage the risks associated with evolving algorithms.
Recommendations
The FDA proposes a "Predetermined Change Control Plan" (PCCP) to be included in premarket submissions. This plan would specify the anticipated modifications to the device (the "what") and the methodology for implementing and validating those changes (the "how"). The development of "Good Machine Learning Practice" (GMLP) is encouraged to ensure that AI/ML algorithms are developed and validated using best practices. Manufacturers should implement robust real-world performance monitoring to ensure that their devices remain safe and effective after deployment.
Regulatory Considerations
The FDA is developing a new regulatory framework tailored to the unique aspects of AI/ML-based SaMD, which will leverage a TPLC approach. The agency has issued an "AI/ML SaMD Action Plan" that outlines its multi-pronged approach, including issuing draft guidance on PCCPs and promoting the harmonization of GMLP. The FDA is actively collaborating with stakeholders to foster innovation while ensuring patient safety. The agency maintains a public list of authorized AI/ML-enabled medical devices to enhance transparency.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations
Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations
AI-enabled medical devices require robust risk assessment to address data drift, bias, and transparency challenges.
The total product lifecycle (TPLC) approach is essential for managing AI-enabled devices, ensuring continuous oversight and updates.
There is a need for improved standardization in AI model validation and performance monitoring to ensure consistency in regulatory submissions.
Effective data management practices, including dataset representativeness and bias control, are critical for AI model development.
Cybersecurity vulnerabilities in AI-enabled medical devices must be proactively addressed to prevent risks to patient safety and data integrity.
Recommendations
AI-enabled device manufacturers should integrate Good Machine Learning Practice (GMLP) principles throughout the device lifecycle.
Marketing submissions should include comprehensive documentation of AI model development, validation, and performance monitoring.
Developers should implement transparency measures, such as model interpretability and explainability, to enhance user trust and understanding.
AI models must undergo rigorous bias evaluation to ensure equitable performance across diverse patient populations.
A predetermined change control plan (PCCP) should be established to allow safe and effective AI model updates post-market without additional FDA submissions.
Regulatory Considerations
FDA encourages early engagement through the Q-Submission Program for AI-enabled device manufacturers.
Compliance with FDA-recognized consensus standards, such as ANSI/AAMI/ISO 14971 for risk management, is recommended.
AI-enabled devices must meet labeling requirements, ensuring that users clearly understand model inputs, outputs, and performance metrics.
Post-market surveillance and continuous monitoring of AI model performance are necessary to ensure ongoing safety and effectiveness.
Cybersecurity measures must be included in regulatory submissions, detailing safeguards against data breaches and unauthorized model modifications.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Assessing clinical meaningfulness in clinical trials for Alzheimer’s disease: A U.S. regulatory perspective
Assessing clinical meaningfulness in clinical trials for Alzheimer’s disease: A U.S. regulatory perspective
In a progressive neurodegenerative illness like Alzheimer's disease, slowing the rate of disease progression is considered a clinically meaningful outcome for patients and their caregivers.
The assessment of what constitutes a clinical benefit is highly dependent on the specific stage of AD being studied, the drug's mechanism of action, and the symptoms present in that patient population.
Direct input from patients and caregivers is critical for understanding disease burden and defining treatment benefits that are truly meaningful from their perspective.
The interpretation of score changes on Clinical Outcome Assessments (COAs) requires full context; an absolute point difference must be considered relative to the study's duration, the expected placebo decline, and the specific disease stage.
Evidence from biomarkers that show an effect on underlying disease pathology provides additional support and increases the persuasiveness of the changes observed on clinical endpoints.
Recommendations
Drug developers should implement multiple "fit-for-purpose" COAs that use different reporters (e.g., clinicians, observers) and methods to generate broad and diverse evidence of a drug's clinical benefit.
Sponsors should utilize both qualitative and quantitative methodologies to explore clinical meaningfulness, including assessing "meaningful within-patient change" throughout the development process.
Developers are encouraged to create and validate new COAs and leverage innovative approaches, such as digital health technologies, to better capture concepts that are relevant to patients, especially in the earliest stages of AD.
Throughout the drug development lifecycle, stakeholders should systematically collect and incorporate patient experience data to ensure that the perspectives, needs, and priorities of patients are meaningfully captured.
Regulatory Considerations
For a drug to gain approval, it must meet the regulatory standard of "substantial evidence of effectiveness," which is typically derived from adequate and well-controlled investigations designed to minimize bias.
The FDA defines clinical benefit as a clinically meaningful effect of a drug on how an individual feels, functions, or survives.
An assessment of clinical benefit is not limited to the primary endpoint; the consistency of findings across multiple endpoints (primary and secondary) is a key consideration during regulatory review.
The accelerated approval pathway may be used for serious conditions with unmet needs based on a surrogate endpoint, but traditional approval requires verification of clinical benefit in confirmatory trials.
The FDA's evaluation includes a benefit-risk analysis, which considers the severity of the disease and the availability of alternative therapies, recognizing that patients and physicians may accept greater risks for life-threatening illnesses.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Biomarker Qualification Program
Biomarker Qualification Program
The traditional process of evaluating biomarkers within the context of a single drug development program is inefficient and creates uncertainty for sponsors. This case-by-case approach leads to redundant efforts, slows down the development of novel therapies, and hinders the broad adoption of promising scientific tools. There is a clear need for a centralized, collaborative pathway to formally validate biomarkers, which can de-risk drug development, encourage innovation, and make the process more predictable and cost-effective for all stakeholders.
Recommendations
Drug developers, academic researchers, and other stakeholders should proactively engage with the FDA through the formal Biomarker Qualification Program to validate biomarkers for specific contexts of use. It is recommended to form public-private partnerships and other collaborations to pool resources and data, which strengthens the evidence package for a biomarker's utility. Developers should use the qualification process to establish a biomarker's value early, making it a publicly available and reliable tool that can accelerate the development of multiple drug products.
Regulatory Considerations
The Biomarker Qualification Program provides a distinct regulatory pathway for establishing a biomarker's validity for a specific Context of Use (COU), separate from an individual Investigational New Drug (IND) or New Drug Application (NDA). The process involves a three-stage submission and review cycle: the Letter of Intent, the Qualification Plan, and the Full Qualification Package. Once qualified, a biomarker is publicly listed and can be incorporated into multiple drug development programs without the need for sponsors to re-submit and re-justify the validation data for that specific COU, streamlining subsequent regulatory reviews.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Collaborative Communities: Addressing Health Care Challenges Together
Collaborative Communities: Addressing Health Care Challenges Together
Collaborative Communities are sustained, multi-stakeholder forums (including patients, industry, academia, and the FDA) dedicated to solving shared challenges in the medical device ecosystem. These communities are not intended to replace formal regulatory mechanisms. They are equipped to perform activities such as:
Developing best practices and strategies.
Generating and evaluating evidence to support novel approaches.
Clarifying ill-defined challenges and generating consensus on definitions.
Addressing issues related to product quality and safety.
Recommendations
The FDA/CDRH does not establish or fund these communities. Instead, the FDA recommends that interested stakeholders convene and lead these groups. The FDA reviews opportunities on a case-by-case basis for participation, considering:
The community's potential public health impact.
Alignment with the CDRH mission, priorities, and resources.
The existence of a formal governance structure, a convener, a plan to measure success, and a mechanism for sustained engagement.
Regulatory Considerations
The FDA's participation in these communities is a strategic priority for advancing regulatory science and fostering responsible medical device innovation. Examples of digital health-related collaborations include those focused on AI/ML, Digital Biomarkers, Digital Health Technologies (DHTs), and Real-World Data (RWD). The outcomes developed by these groups can inform and accelerate the development of science-based solutions to policy and scientific challenges.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Condition-Specific Meeting Reports and Other Information Related to Patients’ Experience
Condition-Specific Meeting Reports and Other Information Related to Patients’ Experience
Patient experience data provides critical context for regulatory review by illuminating disease burden, unmet medical needs, and the aspects of a condition that matter most to patients.
A systematic approach is necessary to ensure patient experience data is robust enough for regulatory consideration, moving beyond anecdotal evidence to scientifically rigorous data collection.
Early engagement between sponsors and the FDA is a key factor for successfully incorporating patient perspectives into a drug development program.
The value of patient-reported outcomes (PROs) and other clinical outcome assessments (COAs) is highly context-dependent, varying significantly across different diseases and patient populations.
Recommendations
Drug sponsors should leverage the FDA's meeting process to discuss their strategies for collecting and submitting patient experience data early in the development lifecycle.
Sponsors should utilize the repository of meeting reports as a learning resource to understand best practices and common challenges in patient-focused drug development for specific conditions.
Patient advocacy groups should actively participate in these discussions to ensure the full spectrum of patient experiences is captured and communicated to both regulators and developers.
Researchers should develop and validate novel tools and methodologies for capturing and analyzing patient experience data that are meaningful for both clinical and regulatory purposes.
Regulatory Considerations
Patient experience data is a key component of the benefit-risk assessment, providing evidence that can inform regulatory decisions regarding a drug's approval and labeling.
The FDA's review of patient experience data is guided by a commitment to patient-focused drug development, as mandated by the 21st Century Cures Act and supported by user fee agreements like PDUFA.
The scientific rigor of data collection and analysis is paramount; for patient experience data to be influential, it must meet high standards of validity and reliability.
Transparency is a core principle, and the publication of these meeting reports is intended to provide clear examples of how patient input can be effectively integrated into regulatory submissions.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.