
Welcome to the sDHT Adoption Library, featuring NaVi
NaVi is a closed-environment AI research assistant that leverages a carefully curated library of more than 300+ vetted documents, including FDA guidance and industry best practices. NaVi helps you search and explore content across the sDHT Adoption Library and Roadmap using natural language questions.
The Library is intended to serve as a living resource. Content is added periodically as new guidance, standards, and peer-reviewed research are released.
Meet NaVi: Your AI-Powered Research Assistant
Library scope and selection
To ensure high-quality, relevant results, the Library follows a predefined scoping approach:
- Inclusions: FDA guidance, non-commercial standards, and peer-reviewed research (2018–Present) focused on sDHTs being used as measurement tools for medical products in U.S.-based clinical trials.
- Exclusions: Materials from single commercial entities, non-U.S. regulatory bodies (except select EMA guidances with direct U.S. cross-relevance), and conference proceedings, and conference proceedings.
Inclusion in the Library does not imply endorsement, completeness, or regulatory acceptability.
Library scope
Resources in the sDHT Adoption Library are identified using a predefined scoping approach and include publicly available FDA guidance, non-commercial standards and guidance, and peer-reviewed research relevant to sDHT use in U.S.-based clinical trials. Materials from single commercial entities, non-U.S. regulatory bodies, conference proceedings, and studies conducted exclusively outside the United States are excluded; inclusion does not imply endorsement or regulatory acceptability.
Last updated 2026: Library content is reviewed and updated on a periodic basis as new eligible materials become available.
Clinical Performance Assessment: Considerations for Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device Data – Premarket Approval (PMA) and Premarket Notification [510(k)] Submission
Clinical Performance Assessment: Considerations for Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device Data – Premarket Approval (PMA) and Premarket Notification [510(k)] Submission
CADe clinical performance studies must address key variables, including reader variability, disease prevalence, and device design differences.
Properly conducted MRMC studies are critical for assessing diagnostic effectiveness, incorporating both unaided and aided reading conditions.
Enriched datasets, while useful for stress testing, must be carefully designed to avoid bias and reflect intended use populations.
The truthing process (establishing reference standards) is essential to validate device performance claims and should be rigorously defined.
The FDA encourages pre-specification of hypotheses, statistical methods, and endpoints to ensure robust and interpretable results.
Recommendations
Design studies with representative patient populations and include diverse subgroups relevant to the device’s intended use.
Use validated statistical methods for MRMC analyses, reporting sensitivity, specificity, and receiver operating characteristic (ROC) curve metrics.
Develop and document a detailed truthing process for establishing reference standards, ensuring consistency and reliability.
Conduct stress testing with enriched datasets to evaluate device performance under challenging conditions but avoid overrepresenting certain subsets.
Submit a complete study protocol and statistical analysis plan, including sample size justification, randomization methods, and scoring techniques.
Regulatory Considerations
CADe devices classified under 21 CFR 892.2050 or 892.2070 must comply with premarket notification requirements, including performance testing and labeling.
Standalone performance assessments may suffice in certain scenarios, but clinical studies are often necessary for substantial equivalence determinations.
Use of foreign clinical data requires justification of its applicability to U.S. populations and medical practice.
FDA expects data integrity controls, such as firewalls and audit trails, to prevent tuning bias in test datasets reused across studies.
The FDA encourages early engagement (e.g., Pre-Submission requests) for feedback on study protocols and regulatory pathways.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device Data – Premarket Notification [510(k)] Submissions
Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device Data – Premarket Notification [510(k)] Submissions
CADe devices must meet classification requirements under 21 CFR 892.2050, including general and special controls, and require FDA clearance through 510(k) submissions.
Each new CADe device or significant modification must demonstrate substantial equivalence to a predicate device in terms of safety and effectiveness.
Robust testing and validation are necessary, including standalone and clinical performance assessments, to evaluate detection accuracy and false positive rates.
Devices with substantive technological differences or new intended uses may require clinical performance assessments.
Enrichment strategies for study populations (e.g., including challenging cases) are encouraged but should not bias performance evaluations.
Recommendations
Clearly describe the CADe algorithm, training datasets, scoring methodologies, and intended use in premarket submissions.
Conduct standalone performance assessments to measure detection accuracy and generalizability.
Compare new devices to predicate devices whenever possible, using consistent datasets and methodologies.
Develop and submit user training materials that address expected device performance, limitations, and appropriate usage scenarios.
Provide comprehensive labeling, including indications for use, directions, warnings, precautions, and performance metrics, to ensure clinician understanding and appropriate application.
Regulatory Considerations
All CADe devices under 21 CFR 892.2050 must comply with 510(k) premarket notification requirements, including general and special controls.
Changes to CADe algorithms or device characteristics must be evaluated for significant impact on safety and effectiveness, potentially requiring new submissions.
Devices with altered indications for use or significant technological differences may need additional clinical performance studies to demonstrate substantial equivalence.
Labeling must comply with 21 CFR Part 801 and provide sufficient information to describe the device, its intended use, and directions for use.
Manufacturers should consult FDA for guidance on substantial modifications or unique device characteristics.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.