Welcome to the sDHT Adoption Library, featuring NaVi
NaVi is a closed-environment AI research assistant that leverages a carefully curated library of more than 300+ vetted documents, including FDA guidance and industry best practices. NaVi helps you search and explore content across the sDHT Adoption Library and Roadmap using natural language questions.
The Library is intended to serve as a living resource. Content is added periodically as new guidance, standards, and peer-reviewed research are released.
Meet NaVi: Your AI-Powered Research Assistant
Library scope and selection
To ensure high-quality, relevant results, the Library follows a predefined scoping approach:
- Inclusions: FDA guidance, non-commercial standards, and peer-reviewed research (2018–Present) focused on sDHTs being used as measurement tools for medical products in U.S.-based clinical trials.
- Exclusions: Materials from single commercial entities, non-U.S. regulatory bodies (except select EMA guidances with direct U.S. cross-relevance), and conference proceedings, and conference proceedings.
Inclusion in the Library does not imply endorsement, completeness, or regulatory acceptability.
Library scope
Resources in the sDHT Adoption Library are identified using a predefined scoping approach and include publicly available FDA guidance, non-commercial standards and guidance, and peer-reviewed research relevant to sDHT use in U.S.-based clinical trials. Materials from single commercial entities, non-U.S. regulatory bodies, conference proceedings, and studies conducted exclusively outside the United States are excluded; inclusion does not imply endorsement or regulatory acceptability.
Last updated 2026: Library content is reviewed and updated on a periodic basis as new eligible materials become available.
Artificial Intelligence in Software as a Medical Device
Artificial Intelligence in Software as a Medical Device
The traditional medical device regulatory paradigm is not designed for the adaptive nature of AI/ML technologies, which can learn and change after they are on the market. A key benefit of AI/ML is its ability to improve performance by learning from real-world data, but this also presents a unique regulatory challenge. To ensure patient safety and device effectiveness, a new, flexible regulatory framework is required that can accommodate these iterative improvements. Transparency and robust monitoring are essential to manage the risks associated with evolving algorithms.
Recommendations
The FDA proposes a "Predetermined Change Control Plan" (PCCP) to be included in premarket submissions. This plan would specify the anticipated modifications to the device (the "what") and the methodology for implementing and validating those changes (the "how"). The development of "Good Machine Learning Practice" (GMLP) is encouraged to ensure that AI/ML algorithms are developed and validated using best practices. Manufacturers should implement robust real-world performance monitoring to ensure that their devices remain safe and effective after deployment.
Regulatory Considerations
The FDA is developing a new regulatory framework tailored to the unique aspects of AI/ML-based SaMD, which will leverage a TPLC approach. The agency has issued an "AI/ML SaMD Action Plan" that outlines its multi-pronged approach, including issuing draft guidance on PCCPs and promoting the harmonization of GMLP. The FDA is actively collaborating with stakeholders to foster innovation while ensuring patient safety. The agency maintains a public list of authorized AI/ML-enabled medical devices to enhance transparency.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations
Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations
AI-enabled medical devices require robust risk assessment to address data drift, bias, and transparency challenges.
The total product lifecycle (TPLC) approach is essential for managing AI-enabled devices, ensuring continuous oversight and updates.
There is a need for improved standardization in AI model validation and performance monitoring to ensure consistency in regulatory submissions.
Effective data management practices, including dataset representativeness and bias control, are critical for AI model development.
Cybersecurity vulnerabilities in AI-enabled medical devices must be proactively addressed to prevent risks to patient safety and data integrity.
Recommendations
AI-enabled device manufacturers should integrate Good Machine Learning Practice (GMLP) principles throughout the device lifecycle.
Marketing submissions should include comprehensive documentation of AI model development, validation, and performance monitoring.
Developers should implement transparency measures, such as model interpretability and explainability, to enhance user trust and understanding.
AI models must undergo rigorous bias evaluation to ensure equitable performance across diverse patient populations.
A predetermined change control plan (PCCP) should be established to allow safe and effective AI model updates post-market without additional FDA submissions.
Regulatory Considerations
FDA encourages early engagement through the Q-Submission Program for AI-enabled device manufacturers.
Compliance with FDA-recognized consensus standards, such as ANSI/AAMI/ISO 14971 for risk management, is recommended.
AI-enabled devices must meet labeling requirements, ensuring that users clearly understand model inputs, outputs, and performance metrics.
Post-market surveillance and continuous monitoring of AI model performance are necessary to ensure ongoing safety and effectiveness.
Cybersecurity measures must be included in regulatory submissions, detailing safeguards against data breaches and unauthorized model modifications.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.
Marketing Submission Recommendations for a Predetermined Change Control Plan for Artificial Intelligence/Machine Learning (AI/ML)-Enabled Device Software Functions
Marketing Submission Recommendations for a Predetermined Change Control Plan for Artificial Intelligence/Machine Learning (AI/ML)-Enabled Device Software Functions
AI-DSFs undergo iterative improvements, necessitating a structured framework for modifications to ensure safety and effectiveness.
PCCPs enable manufacturers to streamline modifications by avoiding repeated marketing submissions, reducing regulatory burden.
Critical elements of a PCCP include data management practices, re-training protocols, performance evaluation, and user update procedures.
Comprehensive risk management and transparency are essential to address potential biases and maintain user trust.
Certain modifications, such as those significantly affecting safety or effectiveness, may still require a new marketing submission.
Recommendations
Structure PCCPs with a clear description of planned modifications, a detailed modification protocol, and a robust impact assessment.
Include methods for data collection, re-training, and performance evaluation aligned with quality system regulations.
Specify user update procedures to communicate changes transparently and ensure safe device use.
Address cybersecurity risks and bias mitigation strategies in modification protocols.
Use the FDA Q-Submission Program to discuss PCCPs prior to submitting marketing applications for AI-DSFs.
Regulatory Considerations
Adherence to 21 CFR Part 820 Quality System Regulations, including design controls and risk management.
PCCPs must include modifications that would otherwise require a PMA supplement or new 510(k) submission.
Modifications implemented under PCCPs must conform to FDA-reviewed protocols and be documented in the device master record.
Transparency to users via device labeling updates and public summaries of authorized PCCPs is required.
Modifications outside the scope of an authorized PCCP or deviations from the protocol require new FDA marketing submissions.
Some summaries are generated with the help of a large language model; always view the linked primary source of a resource you are interested in.